Olympus Diagnostics Clinical Chemistry AU Analyzers

Olympus Diagnostics Clinical Chemistry AU Analyzers Turnkey Laboratory Business Services and Solutions. Refurbished Clinical Chemistry Analyzers. Refurbished LCMS Refurbished GCMS Refurbished Olympus AU400

Atlantic Lab Services offers Clinical Chemistry Analyzers and reagents and expert service for Olympus and Beckman Coulter chemistry analyzers. Our professional team is comprised of manufacturer trained Engineers/Technicians and highly skilled customer service representatives who are committed to providing quality PM and repair services with a stress-free experience. Laboratory equipment is a majo

r investment and one that is important to your lab. Protecting and optimizing that investment on your own is time consuming and expensive. ALS offers a variety of service agreement options to deliver peak instrument performance, reducing your operating costs, and maximizing the productivity of your lab. Atlantic Lab Services offer a range of affordable service plans to improve productivity, increase equipment uptime and utilization, maintain peak performance and lower the total cost of ownership. This extends the lifetime of your equipment investment while providing you convenient access to quality service and parts and eliminating the uncontrollable cost of unplanned maintenance and repairs. Replace your expensive Olympus / Beckman Coulter OEM service agreement with ALS Full Service contract at a lower price without affecting the quality of service. We are here to be your Olympus and Beckman Coulter chemistry analyzers service providers. Atlantic Lab Services offers service agreement options for Beckman Coulter and Olympus chemistry analyzers . Maintaining your laboratory equipment is crucial to the overall productivity of your lab, the long-term performance of your equipment and your total cost of ownership. Service Packages
Full Service Agreement: Includes unlimited emergency repair, two preventive maintenance (PM) per year, replacement parts(except consumable parts), labor and travel, call service support. PM Service Agreement: An economical choice, which includes two scheduled preventive maintenance, PM parts (except consumable parts), labor and travel, call service support. Emergency Repair: Special rate for emergency service labor and parts. Installation and Moving: ALS specialize in servicing Beckman Coulter and Olympus chemistry analyzers installation and moving.

03/09/2017
03/06/2017
Olympus AU2700 Clinical Chemistry AnalyzerPrice starting $32,000.00This powerful performer offers you the broadest 122-t...
03/06/2017

Olympus AU2700 Clinical Chemistry Analyzer
Price starting $32,000.00
This powerful performer offers you the broadest 122-test menu in the market today, including Emit® brand applications, and the benefits from a standardized family.
The Olympus AU2700 provides proven technology for the demanding environment of the high volume laboratory. Designed to meet your needs as a primary analyzer with a broad 122-test menu, the AU2700
features rapid STAT turnaround, true random access testing, and pediatric sampling.

This high speed analyzer can process general, urine, CSF and STAT
chemistries, serum proteins, thyroid assays, therapeutic drugs and drugs of abuse. Compatible standardization between Olympus models include identical userinterfaces, standardized results and reference ranges and the same reagents, consumables and parts for the lowest cost per reportable in the healthcare market today. The AU2700 provides flexible cost-effective solutions for busy laboratories.
The General Characteristics
Test Menu Selection: 125 On-board Parameters: 99 Maximum Tests/Hour 2133 (photometric + ISE) 1600 (photometric only)
Analytical System: Fully selective discrete analytical
Methods: Endpoint Endpoint with self blanking Endpoint with sample blanking Kinetic rate Fixed rate ISE Sample Processing Selection: Single, multiple, or profile Sample Volume: 1 - 25 µL [0.1 µL increments] Sample Type: Serum, plasma, urine, CSF
Sample Tray Capacity: 300 samples by rack 22 samples by carousel
Sample Container: 12 x 75 - 16 x 100 mm tubes 5, 7, 10 mL primary collection tubes
Sample Transport: 10 position bar-coded rack
STAT Compartment: 22 user-definable for STAT, QC, cal, routines enclosed and refrigerated module
Sample Quality Analysis: Lipemia, Hemolysis, Icterus Clot detection Probe crash prevention
Sample Identification: Bar code reader [Maximum 22 Digits; 95 mm]
Sample Bar Code Formats: As mixed bar codes: NW7 Code 39 Code128 2 of 5 interleaved 2 of 5 standard Alone: ISBT code 128
Reagent Identification: Bar code reader Reagent Configuration: Concentrated and full strength
Reagent Volume: R1 and R2: 15 - 250 µL [1 µL increments] Reagent Delivery: One or two reagent pipetter dispensing Reagent probe crash prevention Reagent Storage: 4 - 12° C
Reagent Bottle Capacity: 15, 30, 60, 120 mL Reagent Storage Capacity: R1 = 48, R2 = 48 Reaction Mixture: Minimum = 120 µL Maximum = 430 µL
Reaction Temperature: 37° C
Reaction Incubation Method: Dry Bath Reaction Cell: 6 x 8 x 30 mm nondisposable glass cuvette Reaction Time: 8 min. + 20 sec. (maximum)
Repeat Run: Automatic repeat run Increase or decrease sample volume
Reflex Testing: User defined
Sample Predilution: Dilution ratio 5 - 100 by one-fold increments
ISE Module Analytical System: Flow cell block with ISE
Analytical Tests: Sodium [Na+], Potassium [K+], Chloride [Cl-] Sample Throughput: 267 samples/hour Maximum Test/Hr: 800, if ISE mode only
Sample Type: Serum, plasma, urine [undiluted]
Sample Volume: 20 µL Final
Dilution Ratio: 1:31.5
Measuring Range: Serum and plasma: Sodium 50 - 200 mEq/L Potassium 1.0 - 10.0 mEq/L Chloride 50 - 200 mEq/L Urine: Sodium 10 - 400 mEq/L Potassium 2.0 - 200 mEq/L Chloride 15 - 400 mEq/L
Electrode Composition: Sodium Crown-ether membrane Potassium Crown-ether membrane Chloride Molecular oriented solid membrane Reference Liquid on liquid membrane
Optical Characteristics Photometer: Multi-wavelength diffraction grating spectrophotometer
Light Source: Tungsten-halogen lamp; life 2000 hours
Photometric Modes: Monochromatic or bichromatic
Wavelengths: 340, 380, 410, 450, 480, 520, 540, 570, 600, 660, 700, 750 and 800 nm Light Path: 6 mm Photodetector: Silicon photodiode array Photometric Range: 0.000 to 2.5000
Photometric Sensitivity: 0.0001 OD
Data Processor Interface: Standard RS232C; bidirectional Real time and batch processing Program Storage: 6.4 GB hard drive, CD-ROM drive Patient Storage: Results from up to 60,000 samples Data Input: Alphanumeric keyboard, mouse, or interface Display: 17 in. monitor Printer: Dot matrix Software: Windows® Graphic user interface System status screens User defined operating menu Maintenance training videos Operator manual with links, search Advanced calibration QC trending Auto-QC Daily test statistics User-defined calculated tests Sample and test oriented data editing Multi-level password protection Reaction curve monitor Olympus SUPPORTVISION™ Olympus AU2700® Chemistry-Immuno Analyzer Electrical Requirements Electrical Consumption: 6 KVA [maximum] Current [Circuit Breaker Required]: 30 Amp [standard] 50 Amp with UPS Circuit: Dedicated and noise free Voltage: 208/220 VAC [±10%] single phase Frequency: 60 [±1 Hz] Ground Requirements: Resistance < 100 ohms Location: Power cable length 30 ft. Environmental Requirements Average Heat Output: 10,500 BTU Ambient Temperature: 18 - 32 ± 2° C during measurement Ambient Humidity: 40 - 80% relative humidity Peak Water Consumption: 65 L/hour Water Type: Deionized CAP Type II, bacteria free Supply: Continuous flow Resistivity: > 0.5 Megaohm Pressure: 7 - 57 PSI Control: Shut off valve within 30 ft. AU2700SPECREVB 06.08-5M Drain Requirements Non-hazardous Waste: Built-in waste pump Drain required, Maximum height - 4 ft Dimensions Width: 79 in. Depth: 45 in. Height: 50 in. Weight: 1,540 lbs
for more details: https://www.atlabservices.com/olympus-au2700

Olympus AU640 Clinical Chemistry AnalyzerPrice starting $26,000.00Olympus Diagnostic Systems Division introduces its AU6...
03/06/2017

Olympus AU640 Clinical Chemistry Analyzer
Price starting $26,000.00
Olympus Diagnostic Systems Division introduces its AU640 chemistry immuno system, which is designed for the demanding environments of mid- to large-sized hospitals. This high speed automated analyzer streamlines diverse chemistry-immuno testing to provide the greatest walkaway, while processing up to 1,200 tests per hour. The new AU640 not only incorporates the proven technology of the Olympus AU600, but also includes the latest advances of its new AU400 to increase ease of use and provide more powerful performance. .

AU 640 Specifications
Analytical system Fully automated, for routine, STAT, urine and homogeneous immunoassays
Analytical methods Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE
Simultaneously processed analytes 48 photometric tests, 51 with ISE
Throughput 800 photometric tests/hour; maximum of 1,200 with ISE
Sample feeder Racks with 10 samples each (bar codes on primary tubes and on racks); capacity of 150 samples; continuous loading
Sample tubes In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm
STAT samples Up to 22 positions for STAT samples, bar coded primary tubes
Sample volume 2 – 50 µl in 1 µl steps (1 – 50 µl for repeats)
Reagent supply 48 positions for R1 and R2; refrigerated (4 °C – 12 °C)
Reagent volume 1. reagent: 25 – 300 µl; 2. reagent: 25 – 300 µl; (in 1 µl steps)
Total reaction volume 150 – 550 µl
Reaction cuvette Quartz cuvettes
Reaction time Up to 8 minutes, 40 seconds
Reaction temperature 37 °C
Mixing method With rotating paddles after dispensing sample and reagent
Photometry system Direct assay through the reaction cuvette (0 – 2.5 OD) mono, bichromatic measurements possible
Wavelength 13 different wavelengths between 340 – 800 nm
Cuvette cleaning Comprehensive cleaning with detergents
Calibration Auto calibration, cooled calibrator positions
Quality control Auto QC, cooled QC positions
Test requisition Individual and profile test requisition via on line, mouse, functions keys or touch screen
Safety Clot detection and crash prevention for sample and reagent dispenser
On-line Full uni- and bidirectional communication possible
Software Windows-NT
Dimensions (W x H x D) mm ANL 1,850 x 1,210 x 800; DPR 700 x 1,430 x 700

for more details: https://www.atlabservices.com/olympus-au640

Olympus AU400 Clinical Chemistry AnalyzerPrice starting $22,000.00The new AU 400 system is a fully automated, random acc...
03/06/2017

Olympus AU400 Clinical Chemistry Analyzer
Price starting $22,000.00
The new AU 400 system is a fully automated, random access clinical chemistry analyser with all the benefits of Olympus Systems Compatibility.
With a throughput of 400 photometric tests per hour the system provides high performance analysis, including STAT and ISE capability, in a compact package for small and medium size laboratories.
AU 400 Specifications
Analytical system
Fully automated, for routine, STAT, urine and homogeneous Immuno Assays
Analytical methods
Clinical chemistry and immunological parameters. End point, kinetic assays,
fixed-time-kinetics, optionally ISE
Simultaneously processed analytes
Up to 51 photometric tests + 3 ISE
Throughput
400 photometric tests / hour; maximum of 800 with ISE
Sample feeder
Racks with 10 samples each (bar-codes on primary tubes and on racks);
capacity of 80 samples; continuous loading
Sample tubes
In primary and secondary tubes; diameter from 11.5 to 16 mm;
height from 55 to 102 mm
STAT samples
Up to 22 positions for STAT samples, bar-coded primary tubes
Sample volume
2 – 50 μl in 1 μl steps (1– 50 μl for repeats)
Reagent supply
Refrigerated (4° C – 12° C); 76 positions for R1 / R2
Reagent volume
1. reagent: 25 – 300 μl; 2. reagent: 25 – 300 μl; (in 1 μl steps)
Total reaction volume
150 – 550 μl
Reaction cuvette
Quartz cuvettes
Reaction time
Up to 8 minutes, 40 seconds
Reaction temperature
37° C
Mixing method
With rotating paddles after dispensing sample and reagent
Photometry system
Direct assay through the reaction cuvette (0 – 2.5 OD) mono-, bichromatic
measurements possible
Wave length
13 different wave lengths between 340 – 800 nm
Cuvette cleaning
Comprehensive cleaning with detergents
Calibration
Linear and non linear (linear interpolation), refrigerated calibrator positions
Data processing
Calculated parameters, blank value correction and correlation. Definition of normal
value range, measuring range, pathological values and repeats. Quality controls,
printout of abnormal values, pending sample work list and repeat run sample list
Test requisition
Individual and profile test requisition via on-line, mouse, function keys or optional
touch screen
Safety
Clot detection and crash prevention for sample and reagent dispenser
On-line
Full uni- and bidirectional communication possible
Software
Windows-NT
for more details: https://www.atlabservices.com/olympus-au400

Address

Delray Beach, FL

Alerts

Be the first to know and let us send you an email when Olympus Diagnostics Clinical Chemistry AU Analyzers posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Olympus Diagnostics Clinical Chemistry AU Analyzers:

Share