Dive Tec

Dive Tec Offering technical & servicing experience to recreational divers and instructors for over thirty years.
(1)

Currently servicing equipment for dive operators from Cairns to Port Douglas plus dive schools & SCUBA dive clubs across Australia and overseas.

23/08/2024

The oring on the left came out of a new service kit and didn't notice the size difference.
On attempting to tune I had issues and had to disassemble and found that the two orings on the poppet were a different size.

Akiko, you don't miss out on being featured in the wall of discovery
22/08/2024

Akiko, you don't miss out on being featured in the wall of discovery

For you Epi, welcome to the wall of discovery.
22/08/2024

For you Epi, welcome to the wall of discovery.

Hmmmm
22/08/2024

Hmmmm

Like anything old it will eventually end up cracked.USD [Aqualung] Conshelf 20/21 suffered from this issue. Was resolved...
22/08/2024

Like anything old it will eventually end up cracked.
USD [Aqualung] Conshelf 20/21 suffered from this issue.
Was resolved by bringing out the Conshelf 22.

Dive staff fitted a lip scratcher to a Ocky today.
21/08/2024

Dive staff fitted a lip scratcher to a Ocky today.

A modified high flow port
20/08/2024

A modified high flow port

While working in at Divers Den today I came across this issue.The thread on the back low pressure port is worn and the h...
15/08/2024

While working in at Divers Den today I came across this issue.
The thread on the back low pressure port is worn and the hose even though it still screws in is a sloppy fit.
My question is, should the body be replaced?

Not a well loved reg. 💔 Last serviced March this year!!
04/08/2024

Not a well loved reg. 💔
Last serviced March this year!!

I have no words which is unusual.
04/08/2024

I have no words which is unusual.

Here's another scary equipment malfunction.This 360° swivel has failed after only a month of service and was fitted new....
25/07/2024

Here's another scary equipment malfunction.
This 360° swivel has failed after only a month of service and was fitted new. I do not recommend this product as in my opinion it is a poor quality copy of the proven and reliable Omni Swivel.
It maybe a quarter of the price but doesn't come close in quality.

Today I had a Zeagle 1st and 2nd stage in with excessive Interstage Pressure, test gauge went to 13.8 bar before I shut ...
24/07/2024

Today I had a Zeagle 1st and 2nd stage in with excessive Interstage Pressure, test gauge went to 13.8 bar before I shut it off and this set is used as a ho**ah reg with the IP set at 9.0 bar, the minimum pressure specified by Zeagle.
The cause of this is the ingress of water into the 1st stage with the result being a damaged HP seat.
The effect of the water has water blasted the seat causing the sealing edge to become feathered.
Water was fresh so reg had been washed without dust cap on and I can't emphasise enough how important it is to dry and fit dust cap before washing.
This reg had a full service in June so only a month of use and now this damage plus expense.

Hi all, here's today's surprise.Pic is of an older BCD and it has had the dump retainers disintegrate leaving it destine...
15/07/2024

Hi all, here's today's surprise.
Pic is of an older BCD and it has had the dump retainers disintegrate leaving it destined for the scrap pile.
Yes I can repair it with Delrin fittings from overseas but the cost of repair is prohibitive as by the time I add labour it ends up cheaper to buy a new BCD. Shame it is in as new condition.

This is a purge cover lock on a Cressi Compact 2nd stage which has the retaining lip broken off.Reportedly an isolated i...
12/07/2024

This is a purge cover lock on a Cressi Compact 2nd stage which has the retaining lip broken off.
Reportedly an isolated incident peculiar to The Tropics and has been reported by two well known repair facilities.
Twelve were received as replacements for current and potentially future issues and all covered at no cost to consumer or service centres.
Thanx Scott@Cressi for your ongoing support.

Should this hose be replaced?
11/07/2024

Should this hose be replaced?

Submersible Pressure Gauge [SPG] correct sealing.
09/07/2024

Submersible Pressure Gauge [SPG] correct sealing.

Teching when on holidays.
08/07/2024

Teching when on holidays.

07/07/2024

Another servicing dilemma.

C**k roach icecream, 2nd stage exhaust valve and cause of wet breathing.
05/07/2024

C**k roach icecream, 2nd stage exhaust valve and cause of wet breathing.

Well another day spent "on the tools" at Divers Den and a break from servicing at home.Had a play with two new tools tha...
05/07/2024

Well another day spent "on the tools" at Divers Den and a break from servicing at home.
Had a play with two new tools that Matt just purchased to more accurately tune and function check regulators.
They are the 1st stage flow meter and a Pro Check Water Leak Analyser and precision cracking meter.
Fun times.

Mud wasps, again crack the cylinder valve before fitting your reg otherwise it's going cost you.
05/07/2024

Mud wasps, again crack the cylinder valve before fitting your reg otherwise it's going cost you.

04/07/2024
03/07/2024

Wats wrong with this pic?

Here's an air barrel out of a Scubapro S600, renowned for cracking but this one has an extra crack which I've never seen...
02/07/2024

Here's an air barrel out of a Scubapro S600, renowned for cracking but this one has an extra crack which I've never seen before.
The cracked barrel according to Scubapro service isn't really an issue but in general industry replace them when found cracked.

01/07/2024

Just when I thought the SCUBA service Industry had lifted it's game I find this.
Circled is three orings which have been incorrectly fitted to Aqualung Mikron.
The two orings on the left in the circle are the incorrect size and are the same size as the LP reg swivel ones.
The larger one on the right in the circle was fitted to a HP port plug and is normally fitted to the LP hose 1st. stage end.
Now if you the technician are looking at the schematics and the cheat sheet that comes with the kits these mistakes wouldn't happen.
Though these orings are encapsulated by the 1st stage body, hoses and plugs, they could over time become stressed due to the extra tension on them and fail.
Techs please take more care, read yor service guidelines, schematics and the service kit reference guides.

Address